SC 20A LP tank cleaning machine consists of a gun unit that is installed in the tank and an air driven drive unit. The cleaning procedure will start by opening the valve for the cleaning media and the valve for air supply to the drive unit. The drive unit will then rotate the bottom housing, also forcing the nozzle housing to rotate around its own axis because of the gear system. This creates a criss-cross cleaning pattern on the tank walls. When the cleaning procedure is finalized the valves are to be closed.
Flow | 1,5-10,5 m3/h (25-175 l/min, 6,5-46 gal (US)/min) |
Inlet Pressure | 0,4-1,2 MPa (4-12 bar, 58-175 psi) |
Max Inlet Pressure | 1,2 MPa (12 bar, 175 psi) |
Rotation Speed | 0-6 rpm |
Approx. air consumption: | See graph on page 8 |
Operating temperature: | -20˚C to +40˚C (-4˚F to +104˚F) |
Storage temperature: | -20˚C to +40˚C (-4˚F to +104˚F) |
Noise level: | Earmuffs should always be used when operating machine, noise level may reach over 75 dB |
In contact with cleaning media: | EN 1.4404, EN 1.4310, PTFE, Nitrile, EPDM |
Other parts: | Makers’ standard |
Service space: | Min 350 mm radius from center of deck flange for handling |
Machine length: | L=0,5 m : 5,7 kg (12,6 lb) |
Per additional meter of main pipe: | 1,6 kg (3,5 lb) |
Drive unit: | 2,2 kg (4,9 lb) |